Hours on a report mean nothing until a standard number is attached.
A durability claim must be split into three non-interchangeable lines: corrosion (neutral salt spray, GB/T 10125-2021 / ASTM B117), light ageing (QUV, ASTM G154) and film adhesion (cross-cut, GB/T 9286-2021 / ASTM D3359). Each probes a different failure mode; none substitutes for another. Figures are typical values cited to standards, with measured values governed by the test report.
Neutral salt spray probes resistance to pitting and red rust in a chloride environment, read per GB/T 10125-2021 (aligned with ASTM B117). Published typical figures place 304 with PVD at NSS ≥ 240 h and 316L with PVD at 500 h without red rust. Salt fog and UV ageing are not the same and cannot be converted into one another.
UV ageing combines fluorescent UV with condensation or spray cycles to observe colour shift, chalking and gloss loss, commonly read per ASTM G154. High-UV plateaus, large glazed roofs and exterior signage need this line; quoting salt-spray hours alone for an interior project answers the wrong question.
The cross-cut test measures film-to-substrate adhesion per GB/T 9286-2021 (aligned with ASTM D3359 5B). For PVD, patinated and coated systems, adhesion governs peeling while salt spray governs rusting — two things routinely conflated.
A technical annex should list environment class, substrate grade, film system, salt-spray basis and duration, QUV basis and duration, adhesion grade, colour-deviation basis, and the clause that measured values follow the test report. Without the environment class, no number of hours can be judged sufficient.
| Test | Failure mode | Basis | Typical figure | Use |
|---|---|---|---|---|
| Neutral salt spray (NSS) | Pitting / red rust | GB/T 10125-2021 | ≥ 240 h;316L+PVD 500 h | Coastal / waterside |
| UV ageing (QUV) | Colour shift / chalking | ASTM G154 | ≥ 500 h | Exterior / high UV |
| Cross-cut adhesion | Peeling / delamination | GB/T 9286-2021 | Grade 0 | All film systems |
| Film hardness | Scratching | Vickers method | Per report | High-touch surfaces |
| Thermal resistance | Film structure change | Thermal shock | Per report | Luminaires / oven trim |